Hill, Sam ORCID: https://orcid.org/0000-0001-6829-1084 and Dixon, Steve
(2014)
Localisation of defects with time and frequency measurements using pulsed arrays.
NDT & E International, 67.
pp. 24-30.
Abstract
The frequency dependent directivity of the periodic permanent magnet transducer is used to extract information about the position of any discontinuities present in a sample. Two approaches are used: narrowband excitation and broadband pulsed generation. Simultaneous narrowband excitation, with the appropriate frequency, can be used to steer the ultrasound to a particular angle. Broadband excitation emits a wavefront that extends over a large range of angles, with the frequency of the wavefront varying smoothly as a function of angle. Using these two approaches, two-dimensional maps of any defects present in the sample can be obtained.
| Item Type: | Article |
|---|---|
| Status: | Published |
| DOI: | 10.1016/j.ndteint.2014.06.008 |
| Subjects: | Q Science > QC Physics T Technology > TA Engineering (General). Civil engineering (General) |
| School/Department: | York Business School |
| URI: | https://ray.yorksj.ac.uk/id/eprint/10526 |
University Staff: Request a correction | RaY Editors: Update this record
Altmetric
Altmetric